Alimentation à découpage
Un réglage parfait pour les petits panneaux de contrôle.
- Fonctionnement possible à une température ambiante de –40 °C à 70 °C
- Entrée c.c. prise en charge (90 à 350 Vc.c.)
- Fonction d’augmentation de puissance jusqu’à 120 % (60 W et 120 W)
- Fonction d’augmentation de puissance jusqu’à 150 % (240 W et 480 W)
- Sortie d’alarme de sous-tension (240 W et 480 W)
- Montage côte à côte possible (jusqu’à 55 °C)
- Résistance aux vibrations de 5G et tension de sortie anormale 300 Vc.a. pris en charge pour 1 seconde.
- Le revêtement de la plaquette de circuits imprimés assure une protection contre la poussière, les gaz corrosifs et l’humidité.
- Homologation pour 3 000 m d’altitude.
- Conformité RoHS
Ordering information
100 to 240 VAC |
||||||
Specifications
115 VAC input1 |
||||||
230 VAC input1 |
||||||
Voltage range2 |
Single-phase, 85 to 264 VAC, 90 to 350 VDC, 265 to 300 VAC (1 second) |
|||||
Frequency2 |
||||||
Voltage adjustment range3 |
||||||
Input variation influence4 |
||||||
Load variation influence5 |
||||||
Yes, 130% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) |
||||||
Operating ambient temperature6 |
−40 to 70°C (Derating is required according to the temperature.) (with no condensation or icing) |
|||||
Yes (For up to two Power Supplies, external diodes are required.) |
||||||
|
||||||
2.
Do not use an inverter output for the product. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the product may result in ignition or burning.
If the input is connected to a UPS, do not connect a UPS with a square-wave output.
Doing so will cause the internal temperature of the product to increase, possibly causing smoking or burning.
3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than 28 V min of the voltage adjustment range. When adjusting the output voltage, confirm the actual output voltage from the product and be sure that the load is not damaged.
2.
Do not use an inverter output for the product. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the product may result in ignition or burning.
If the input is connected to a UPS, do not connect a UPS with a square-wave output.
Doing so will cause the internal temperature of the product to increase, possibly causing smoking or burning.
3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than 28 V min of the voltage adjustment range. When adjusting the output voltage, confirm the actual output voltage from the product and be sure that the load is not damaged.
Brochures
Afficher tout brochuresDatasheets
Afficher tout datasheetsManuels
Afficher tout manuelsS'abonner aux mises à jour du produit
Newsletters sur les innovations produit, les solutions et les services, directement dans votre boîte de réception.
Merci pour votre abonnement à eNews d'Omron. Vous recevrez prochainement un e-mail de confirmation de notre part, contenant un lien qui activera votre abonnement. Cette méthode permet d'observer les dispositions légales et de nous assurer que personne n'utilisera à tort votre adresse e-mail.
Nous rencontrons des problèmes techniques. Votre demande ne peut être traitée. Veuillez nous excuser et ré-essayer plus tard. Détails :
DownloadDocumentation du produit
Téléchargez des fiches techniques, des manuels et des brochures.
Parcourir le centre de téléchargementCours de formation
Bénéficiez de la formation de nos meilleurs ingénieurs. Niveau débutant à avancé.
Afficher les cours de formation