H3CR

Fonctions

Série de minuteries multifonctions DIN 48 x 48 mm

Cette gamme élaborée de minuterie vous offre une minuterie multifonction, une minuterie double, une minuterie étoile-triangle et un retard à la mise hors tension.

  • Façade/embrochable 48 x 48 mm
  • Modèles haute/basse tension (sauf -H et -G)
  • 0,05 s à 300 h (sauf -H et -G)
  • DPDT, 5 A à 250 Vc.a.
  • Transistor 100 mA à 30 Vc.c.
Caractéristiques et références

Ordering information

Output

Number of pins

Supply voltage

Time range

Operating mode

Order code

Relay DPDT

11

100 to 240 VAC/100 to 125 VDC

0.05 s to 300 h

ON-delay, flicker OFF start, flicker ON start, signal ON/OFF-delay, signal OFF-delay, interval

H3CR-A 100-240AC/100-125DC

24 to 48 VAC/12 to 48 VDC

H3CR-A 24-48AC/12-48DC

Transistor

24 to 48 VAC/12 to 48 VDC

0.05 s to 300 h

H3CR-AS 24-48AC/12-48DC

Relay DPDT

8

100 to 240 VAC/100 to 125 VDC

0.05 s to 300 h

ON-delay, flicker ON start,
interval, one-shot

H3CR-A8 100-240AC/100-125DC

24 to 48 VAC/12 to 48 VDC

H3CR-A8 24-48AC/12-48DC

Transistor

24 to 48 VAC/12 to 48 VDC

0.05 s to 300 h

H3CR-A8S 24-48AC/12-48DC

Relay SPDT

100 to 240 VAC/100 to 125 VDC

H3CR-A8E 100-240AC/100-125DC

24 to 48 VAC/VDC

H3CR-A8E 24-48AC/DC

Relay DPDT

11

100 to 240 VAC

0.05 s to 30 h

Flicker OFF start

H3CR-F 100-240AC

24 VAC/VDC

H3CR-F 24AC/DC

8

100 to 240 VAC

H3CR-F8 100-240AC

24 VAC/VDC

H3CR-F8 24AC/DC

11

100 to 240 VAC

0.05 s to 30 h

Flicker ON start

H3CR-FN 100-240AC

24 VAC/VDC

H3CR-FN 24AC/DC

8

100 to 240 VAC

H3CR-F8N 100-240AC

24 VAC/VDC

H3CR-F8N 24AC/DC

Time-limit contact and instantaneous contact

100 to 120 VAC

Star-delta

H3CR-G8EL 100-120AC

200 to 240 VAC

H3CR-G8EL 200-240AC

DPDT

8

100 to 120 VAC

0.05 to 12 s

Power OFF-delay

H3CR-H8LS 100-120AC

200 to 240 VAC

H3CR-H8LS 200-240AC

24 VAC/VDC

H3CR-H8LS 24AC/DC

100 to 120 VAC

0.05 to 12 m

H3CR-H8LM 100-120AC

200 to 240 VAC

H3CR-H8LM 200-240AC

24 VAC/VDC

H3CR-H8LM 24AC/DC

Accessories

 

Name/specifications

Order code

Flush-mounting adapter

Y92F-30

Protective cover

Y92A-48B

Front connecting socket

8-pin, finger-safe type, DIN-rail

P2CF-08-E

Front connecting socket

11-pin, finger-safe type, DIN-rail

P2CF-11-E

Back connecting socket

8-pin

P3G-08

11-pin

P3GA-11

 

Name/specifications

Order code

Time setting ring

Setting a specific time

Y92S-27

Limiting the setting range

Y92S-28

Panel cover

Light grey (5Y7/1)

Y92P-48GL

Black (N1.5)

Y92P-48GB

Specifications

 

Accuracy of operating time

±0.2% FS max. (±0.2% ±10 ms max. in a range of 1.2 s)

Influence of voltage

±0.2% FS max. (±0.2% ±10 ms max. in a range of 1.2 s)

Influence of temperature

±1% FS max. (±1% ±10 ms max. in a range of 1.2 s)

Ambient temperature

Operating: -10 to 55°C (with no icing),
storage: -25 to 65°C (with no icing)

Life expectancy

Mechanical

20,000,000 operations min. (under no load at 1,800 operations/h)

Electrical

100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h)

Size in mm (H×W×D)

48×48×66.6 (H3CR-A, -F), 48×48×78 (H3CR-G, -H)

Setting error

±5% FS ±50 ms

Degree of protection

IP40 (panel surface)

Weight

Approx. 90 g

 

Vous avez une question ?

Nous sommes prêts à vous aider.

Contactez-nous.

S'abonner aux mises à jour du produit

Newsletters sur les innovations produit, les solutions et les services, directement dans votre boîte de réception.

Merci pour votre abonnement à eNews d'Omron. Vous recevrez prochainement un e-mail de confirmation de notre part, contenant un lien qui activera votre abonnement. Cette méthode permet d'observer les dispositions légales et de nous assurer que personne n'utilisera à tort votre adresse e-mail.

Nous rencontrons des problèmes techniques. Votre demande ne peut être traitée. Veuillez nous excuser et ré-essayer plus tard. Détails :

Download

Documentation du produit

Téléchargez des fiches techniques, des manuels et des brochures.

Parcourir le centre de téléchargement

Cours de formation

Bénéficiez de la formation de nos meilleurs ingénieurs. Niveau débutant à avancé.

Afficher les cours de formation