Spécifications
| Drive control method | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control |
| Drive supply voltage | 230 V three phase |
| Max. motor output at constant torque | 0.2 kW |
| Max. motor output at variable torque | 0.4 kW |
| Built in EMC filter | |
| Degree of protection (IP) | IP20 |
| Compatible motor type | Induction or asynchronous motor, Permanent magnet motor |
| Communication port(s) | EtherCAT Slave, USB |
| Communication option(s) | None |
| Product Height (unpacked) | 127 mm |
| Product Width (unpacked) | 68 mm |
| Product Depth (unpacked) | 98 mm |
| Product Weight (unpacked) | 500 g |
| Finless type |
Accessoires
| AX-FER2102-PE | Inductance ferrite, 21 mm de diamètre, pour variateurs de 2,2 kW et en dessous |
|
|
| AX-FIC2008-SE | Filtre RFI M1 Footprint, 8 A, 3~ 200 V c.a., pour les modèles de 0,2 à 0,7 kW, conforme UL |
|
|
| AX-M1-S1 | Bride de blindage M1 taille 1 (AB002/AB004/AB007 et A2002/A2004/A2007) |
|
|
| AX-RAI02920030-DE | Réacteur d'entrée CA, 3 A, 2,92 mH, pour puissance 0,2kW, 200 VCA, 3 phases |
|
|
| AX-RAO11500026-DE | Réactance c,a, côté sortie pour , JX/ MX2/ RX series, 2,6 A, 11,5 mH, 0,1, 0,2 et 0,4 kW single et three phase, 200 VAC |
|
|
| AX-RC10700032-DE | Réactance c,c, côté entrée pour JX/ MX2/ RX series, 3,3 A, 10,7 mH, 0,1 et 0,2 kW single phase et 0,4 kW three phase, 200 V AC |
|
|
| AX-RC21400016-DE | Réactance c,c, côté entrée pour JX/ MX2 series, 1,6 A, 21,4 mH, 0,1/0,2 kW three phase, 200 VAC |
|
|
| AX-REM00K1100-IE | Résistance de freinage, 100 W, 100 ohms nominal |
|
|
| AX-REM00K2100-IE | Résistance de freinage, 200 W, 100 ohms nominal |
|