Kenmerken

2-in-1 digitale vezelversterker

De E3X-MDA integreert twee digitale vezelversterkers in één slanke behuizing. In toepassingen waarbij twee objecten tegelijkertijd gedetecteerd moeten worden, biedt de E3X-MDA een praktische oplossing die ruimte en insteltijd bespaart.

  • Twee digitale versterkers in één slanke behuizing
  • Uitvoering met twee uitgangen leverbaar voor aan/uit of gebied (tussen twee drempelwaarden)
  • Functies voor signaalvergelijking (AND, OR, enz.)

Logische bewerking zonder PLC

Logic operations withour PLC.jpg

The AND and OR functionality for the two fiber channels allows simple signal processing without the need for a PLC. This allows the addition of sensor checks to machines without reprogramming the PLC.

Ruimte- en kostenbesparend

Space and cost reduction.jpg

The 2 in 1 amplifier replaces two standard amplifiers reducing space requirements and hardware cost.

Specificaties & bestelinfo

Ordering information

 

Item

Functions

Order code

NPN output

PNP output

Pre-wired

AND/OR output

E3X-MDA11

E3X-MDA41

Fiber amplifier connector1

AND/OR output

E3X-MDA6

E3X-MDA8

Fiber amplifier connectors

Shape

Type

Comment

Order code

 

Fiber amplifier
connector

2 m PVC cable

E3X-CN21

 

30 cm PVC cable with M12 plug connector (4 pin)

E3X-CN21-M1J 0.3M

30 cm PVC cable with M8 plug connector (4 pin)

E3X-CN21-M3J-2 0.3M

Specifications

Item

E3X-MDA

Light source (wave length)

Red LED (650 nm)

Power supply voltage

12 to 24 VDC±10%, ripple (p-p) 10% max.

Protective circuits

Power supply reverse polarity protection, output short-circuit protection, mutual interference prevention

Response time

Super-high-speed mode

130 µs for operation and reset respectively

Standard mode

1 ms for operation and reset respectively

High-resolution mode

4 ms for operation and reset respectively

Sensitivity setting

Teaching and digital up/down keys

Functions

Power tuning

Light emission power and reception gain, digital control method

Timer function

Select from OFF-delay, ON-delay, or one-shot timer.
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments,
200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1 s-increments)

I/O settings

Output setting (select from channel 2 output, AND, OR, leading edge sync, falling edge sync, or differential output)

Digital displays

Select from the following: Incident level for channel 1 + incident level for channel 2, Incident level + threshold, incident level percentage + threshold, incident light peak level + no incident light bottom level, minimum incident light peak level + maximum no incident light bottom level, long bar display, incident level + peak hold, incident level + channel

Degree of protection

IEC 60529 IP50 (with protective cover attached)

 


1. Order connector separately.
1. Order connector separately.

Abonneer u op productupdates

Nieuwsbrieven over productinnovaties, oplossingen en ondersteuning, direct in uw inbox

Dank u wel voor uw aanmelding voor Omrons eNews. Binnenkort ontvangt u een e-mail van ons. Deze e-mail bevat een link die uw aanmelding voor toezending van onze eNews activeert. Deze methode hanteren wij om te voldoen aan wettelijke voorschriften alsmede om er zeker van te zijn dat niemand uw e-mailadres misbruikt.

Wij ondervinden technische problemen. Uw formulierinzending is niet gelukt. Onze verontschuldigingen hiervoor, probeer het later nog een keer. Details: [details]

Download

Productdocumentatie

Download datasheets, manuals en brochures.

Browse downloadcentrum

Trainingen

Volg een training bij onze beste technische specialisten. Van beginner tot gevorderd niveau.

Bekijk onze trainingen